Pump
Testing
Facilities
We have two comprehensive pump performance test facilities.
Bollington Indoor test facility - up to 600m3/hr
Adlington Outdoor test facility - up to 36,000m3/hr (10,000 l/sec)
Hydrostatic and NPSH testing is also undertaken at both sites.
The Adlington test facility is serviced by a 40 tonne crane giving us the ability to handle even the largest pump units.
Tests can be carried out to the following standards:
ISO 2548: 1973 BS5316 Part 1 1976
Specification for acceptance tests for centrifugal mixed flow and axial pumps
– Class C tests
ISO 3555:1977 BS5316 Part 2 1977
Specification for acceptance tests for centrifugal mixed flow and axial pumps
– Class B tests
Interpretation of raw data can be as required by the above standards or to other codes e.g. API 610, client’s in-house codes etc.
Client or third party witnessing of tests is welcomed.
Our digital instrumentation covers a wide range of measurement, with traceable calibration certification.
Testing of client’s pumps for performance verification or up-grading, can be carried out.
All test procedures are documented and certification documentation provided.
Please contact us for details of our charges. |